Sau: Heming
Fiber rau Tsev (FTTH)yog ib hom kev siv thev naus laus zis uas cov teeb liab kev sib txuas lus raug xa los ntawm lub hauv paus ntsiab lus ncaj qha rau cov neeg siv khoom los ntawm fiber ntau optic cables. Nyob rau hauv kev sib piv nrog ib txwm siv networks raws li tooj liab-raws li technology, FTTH muab ib tug ntau dua theem ntawm bandwidth thiab cov ntaub ntawv ceev, raws li zoo raws li lub peev xwm mus xa cov ntaub ntawv nyob rau hauv ntau qhov kev ncua deb.
Tsis tas li ntawd, vim muaj kev loj hlob ntawm huab xam, cov kev pabcuam video streaming, kev ua si hauv online thiab cov khoom siv hauv tsev ntse, qhov kev xav tau rau siab -kev nkag tau nrawm nrawm tau nce zuj zus. Yog li FTTH tau dhau los ua qhov dav tshaj plaws - siv thev naus laus zis thoob plaws ntiaj teb rau tiam tom ntej broadband xa tawm.

Fiber Rau Lub Tsev Architecture: PON thiab AON

Ob fiber optics architectures yog siv nyob rau hauv FTTH networks hnub no:
Passive Optical Network (PON)
Active Optical Network (AON)
Qhov sib txawv tseem ceeb ntawm ob lub tuam txhab yog PON tes hauj lwm xa cov ntaub ntawv siv passive optical splitters, whereas AON tes hauj lwm siv hluav taws xob nquag (xws li Ethernet keyboards thiab routers) kom nthuav dav thiab tswj cov ntaub ntawv teeb liab. Ob hom kev tsim vaj tsev no nthuav tawm ntau tus yam ntxwv sib txawv, muaj zog, tsis muaj zog thiab siv rooj plaub.
Nkag siab txog Fiber Optics Technology
Txhawm rau nkag siab FTTH tes hauj lwm zoo dua, koj yuav tsum xub paub txog cov tshuab fiber ntau optics. Fiber optic thev naus laus zis siv cov kab teeb ci uas taug kev los ntawm fiber ntau optic cable raws li tus neeg nqa khoom nruab nrab rau kev thauj cov ntaub ntawv. Optical fibers tuaj yeem tsim los ntawm iav lossis yas, muab qhov qis qis thiab muab siab - muaj peev xwm xa cov ntaub ntawv muaj peev xwm - ua rau lawv nyiam nruab nrab rau feem ntau cov kev sib txuas lus niaj hnub no.
Txoj Cai Kev Sib Txuas Lus:
Optical fibers sivtag nrho internal reflectionraws li kev xa tawm tswv yim. Kev xa tawm ntawm lub teeb los ntawm cov tub ntxhais fiber ntau txuas ntxiv qhia txog lub teeb ntawm ib thaj tsam mus rau lwm qhov, yog li xyuas kom meej tias cov teeb liab tuaj yeem kis tau ntev dua nrog kev poob qis.
Fiber ntau hom:
Ib hom Fiber (SMF)- Lub taub me me (8-10 µm), ua haujlwm hauv ib hom kev nthuav tawm. Tsawg attenuation thiab ntev -qhov deb siab-bandwidth kis tus yam ntxwv ua rau hom fiber ntau haum rau kev siv nyob deb.
Multi-Mode Fiber (MMF)- Cov tub ntxhais txoj kab uas hla loj dua (50 µm lossis 62.5 µm), txhawb nqa ntau hom kev nthuav tawm vim yog modal dispersion. Multi- hom fiber ntau feem ntau yog siv rau luv- daim ntawv thov nyob deb.
Kev xa tawm thiab txais txais:
Optical signals yog kis tau thiab tau txais siv optical transmitters (laser diodes los yog lub teeb -emitting diodes) uas hloov hluav taws xob teeb liab mus rau optical signals. Thaum kawg tau txais, cov teeb liab kho qhov muag tau hloov pauv rov qab rau hauv cov teeb liab hluav taws xob siv photodetectors.
Kev ntsuas tseem ceeb:
Bandwidth- Cov ntaub ntawv siab tshaj plaws txhawb nqa los ntawm fiber ntau
Attenuation- Teeb liab poob hauv dB/km
Latency- Lub sijhawm rau lub teeb liab taug kev los ntawm tus xa mus rau tus txais
Passive Optical Network (PON)
PONyog ataw tes-rau-ntau ntaupassive optical fiber nkag network uas tsis tas yuav siv hluav taws xob siv hluav taws xob nruab nrab ntawm tus neeg muab kev pabcuam thiab qhov kawg -cov neeg siv. Nyob rau hauv tus txheej txheem PON configuration, lubOLT (Optical Line Terminal)yog nyob ntawm qhov chaw ua haujlwm hauv nruab nrab, thiab OLT faib cov teeb liab kho qhov muag rau ntau yamOptical Network Units (ONUs)los yogOptical Network Terminals (ONTs)los ntawm passive optical splitters.
Yuav Ua Li Cas PON System Ua Haujlwm:
PON systems sivSijhawm -Division Multiple Access (TDMA):
Hauv qab:OLT tshaj tawm rau txhua ONUs
Upstream:ONUs xa mus rau hauv lub sijhawm teem sijhawm
Cov qauv no muab kev pom zoo siv fiber ntau nrog tsawg kawg ntawm cov nroj tsuag lub cev.
Loj PON Standards:
GPON (Gigabit{0}}muaj peev xwm Passive Optical Network)- Txhais los ntawm ITU-T thiab siv dav
Downstream tus nqi: 2.5 Gbps, Upstream tus nqi: 1.25 Gbps
Zoo heev encapsulation efficiency nrog GEM
Advanced QoS rau lub suab, video, thiab cov ntaub ntawv kev pabcuam
Daim ntawv thov:Cov zej zog loj hauv zej zog, Ntau - kev pabcuam broadband nkag network
EPON (Ethernet Passive Optical Network)- Tus qauv tsim los ntawm IEEE, Ethernet-raws li
Symmetrical upstream thiab downstream: 1.0 Gbps (10G-EPON yeem)
Yooj yim tswj network
Tau tshaj Ethernet networks uas twb muaj lawm
Daim ntawv thov:Hauv nroog thiab nyob deb nroog broadband, Tus nqi -sensitive FTTH xa tawm

Active Optical Network (AON)
IbAONmuab ibtaw tes-rau- taw tesfiber nkag architecture los ntawm lub hauv paus hloov / router rau txhua tus neeg siv kawg ntawm kev mob siab rau fiber ntau, nrog rau cov bandwidth tshwj xeeb thiab kev tswj hwm kev pabcuam.
Feem ntau suav nrog Ethernet thev naus laus zis, yooj yim txuas rau LAN / WAN tes hauj lwm uas twb muaj lawm
Yuav siv tau raws li ib qho kev sib koom tes tsis tas yuav muaj PON
Fiber Point-rau-Point (P2P) Kev Txuas:
Central chaw ua haujlwm txuas ncaj qha rau cov neeg siv khoom qhov chaw ntawm fiber ntau
Txhua tus neeg siv khoom muaj nplooj siab fiber ntau, muab cov bandwidth tshwj xeeb thiab yoog raws
Siv tau Ethernet infrastructure (DSL/FTTH) uas twb muaj lawm
Tshem tawm kev sib koom tes → bandwidth siab tshaj plaws, rov ua dua, thiab rov ua dua
Fiber Hook-Ups hauv P2P:
Flat Patch Vaj Huam Sib Luag:Mounted nyob rau hauv phab ntsa qhov chaw, ntau fiber ntau connectors
Angle Patch Vaj Huam Sib Luag:Mounted ntawm qhov chaw nkag, hloov tau yooj yim
Bright Patch Vaj Huam Sib Luag:Ntau txoj kev teeb pom kev zoo, ua rau ntau - taw tes nkag
Hla Txuas:Kev sib txuas ntawm tes hauj lwm los yog qhov chaw muab kev nkag mus rau ib qho kev sib koom tes
Cov yam ntxwv tseem ceeb:
Mus txog 10 Gbps nplooj siab bandwidth
Advanced QoS thiab kev tswj tsheb
Ib qho yooj yim kev koom ua ke nrog Ethernet infrastructure uas twb muaj lawm
Kev siv:
Enterprise broadband nkag
High -kev ua haujlwm pabcuam
WDM Active Optical Network (WDM AON)

Cov ntsiab lus:Muab ib lub wavelength rau txhua tus neeg siv ntawm ib qho fiber ntau
Cov yam ntxwv tseem ceeb:
Kev siv bandwidth siab tshaj plaws
Dedicated bandwidth rau ib tus neeg siv
Ntev - kis tau tus mob nyob deb yam tsis muaj repeaters ntxiv
Kev siv:
Cov lag luam loj
Data center kev sib txuas
Ntev -qhov deb siab- muaj peev xwm nkag tau rau hauv tes hauj lwm
Cov ntsiab lus tseem ceeb:
OLT:Feem ntau muab tso rau hauv Ethernet hloov
ONU/ONT:Dedicated fiber termination
Hloov / Routers:Kev xa xov xa tawm, kev nthuav dav, kev tswj xyuas network
Qhov zoo:
Dedicated bandwidth rau txhua tus neeg siv
Saj zawg zog network tswj thiab QoS tswj
Txhawb nqa ntev - kis tau tus mob
Kev txwv:
Tus nqi xa tawm ntau dua li PON
Ntxiv zog thiab kev txij nkawm
Lub tshuab ua haujlwm tsis ua haujlwm yuav ua rau poob kev pabcuam
AON vs. PON Sib piv
Network Architecture:
PON: Point-rau-Multipoint ntawm passive splitters
AON: Taw tes-rau-Point nrog active switching
Bandwidth:
PON sib koom bandwidth
AON muab kev pabcuam bandwidth
Latency:
PON: qis, siv TDMA teem sijhawm
AON: ruaj khov, tshwj tsis yog lub tshuab ua haujlwm tsis ua haujlwm
Kis qhov nrug:
PIB: ~ 20 km
AON: txuas ntxiv los ntawm kev ua kom nquag plias
Nqi thiab Kho:
PON: qis CAPEX thiab OPEX
AON: tus nqi siab dua, tab sis kev ua tau zoo dua
FTTH Network Tsim thiab xa tawm
Network Design muaj xws li:
Kev npaj thiab kev xaiv topology
Kev xaiv khoom siv thiab kev npaj peev txheej
Kev xa tawm, kev teeb tsa, thiab kev sim
Topologies:Lub hnub qub, Ntoo, Nplhaib - txhua tus muaj kev lag luam - tawm ntawm tus nqi thiab kev ntseeg siab
Kev sim:OTDR xeem ua rau txhua qhov fiber ntau los xyuas kom meej ntev -lub sij hawm ruaj khov
Xaus
AON:Qhov zoo tshaj plaws rau cov lag luam uas xav tau cov bandwidth siab, tsis tshua muaj latency, thiab cov kev pabcuam tshwj xeeb
PON:Qhov zoo tshaj plaws rau qhov loj - thaj chaw FTTH kev xa tawm uas yuav tsum tau them tus nqi- kev sib txuas lus yooj yim thiab ua haujlwm yooj yim
Rau feem ntau hauv nroog FTTH xa tawm,PONyog qhov kev lag luam tshaj plaws thiab kev daws teeb meem.AONyog qhov zoo dua rau cov ntawv thov uas xav tau kev lees paub bandwidth thiab kev pabcuam siab heev.
